ATTENTION:
OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES
Removal/Installation of Major Assemblies -
Ion Elite Edge (cont’d)
Troubleshooting Information - Removal/Installation of Major Assemblies -
Ion Elite Edge
Megatouch Ion Technical Reference Manual
SCREW
LOCATIONS
BENEATH
ANTI-SKID
CIRCLE
SCREWS
SECURING
BASE (12
PLACES)
8. Remove the additional 12 screws outside the circle that are securing the bottom cover. See
Figure 2. NOTE: When removing the last few screws, be sure to hold the cover in place. If
the cover is not properly secured, it may cause injury to the operator and/or damage the
cover.
9. Separate the inverter from the Velcro strip on the game base, then completely remove the base.
10. Remove the 2 wire connectors from the bill acceptor. See Figure 3.
FIGURE 2 - ELITE EDGE - BASE AND ANTI-SKID CIRCLE REMOVAL