MERIT INDUSTRIES Ion Rx Service Manual Page 124

  • Download
  • Add to my manuals
  • Print
  • Page
    / 208
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 123
COPYRIGHT © 2009 MERIT INDUSTRIES, INC.
ATTENTION:
OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES
Removal/Installation of Major Assemblies -
Ion Aurora
Troubleshooting Information - Removal/Installation of Major Assemblies -
Ion Aurora
Megatouch Ion Technical Reference Manual
Power Supply Removal
1. Turn off and unplug the game.
2. Unlock the rear door and open if it is hinged, or remove if it is detachable.
3. Reach under the center of the top of the cover to locate the rotary draw latch (see Figure 1). Turn
the wing on the latch counterclockwise to disengage.
FIGURE 1 - ROTARY DRAW LATCH INSIDE TOP COVER
FIGURE 2 - SCREW IN CENTER OF BOTTOM COVER
4. Unscrew the screw located in the center of the bottom of the cover (see Figure 2). Slowly lift the
cover and disconnect the ground wire.
5. Disconnect the power cord from the power supply. Remove the wing nut securing the OSD board
and detach the board from the Velcro on the power supply bracket. Carefully set the OSD board
aside. See Figure 3.
FIGURE 3 - OSD BOARD
POWER SUPPLY
CORD
SCREW AND
NUT SECURING
OSD BOARD
Page view 123