COPYRIGHT © 2009 MERIT INDUSTRIES, INC.
ATTENTION:
OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES
Removal/Installation of Major Assemblies -
Ion Aurora Widescreen
Troubleshooting Information - Removal/Installation of Major Assemblies -
Ion Aurora Widescreen
Megatouch Ion Technical Reference Manual
Credit Card Reader Removal
1. Turn off and unplug the game.
2. Unlock the rear door and open it.
3. Reach under the center of the top of the cover to locate the rotary draw latch (see Figure 1). Turn
the wing on the latch counterclockwise to disengage.
FIGURE 1 - ROTARY DRAW LATCH INSIDE TOP COVER
FIGURE 2 - SCREW IN CENTER OF BOTTOM COVER
4. Unscrew the screw located in the center of the bottom of the cover (see Figure 2). Slowly lift the
cover and disconnect the ground wire.
5. Place something in front of the game to brace the bezel once the strain relief cord is undone, then
remove the screw at the center of the marquee bezel and the 2 screws on the back of the bezel.
Remove the nut and washer securing the security bolt inside the CPU section (see Figure 3).
FIGURE 3 - SCREWS ON FRONT AND BACK OF BEZEL
SCREW
THROUGH
MARQUEE
SCREWS O
N
BACK OF BEZE
L
(2 PLACES
)
SECURITY BOLT,
WASHER AND NU
T
Page view 133